ACI 530 Code


Veneers

Design and detail flashing and weep holes in exterior veneer to divert water to the exterior. Weepholes shall be at least 3/16 in. (5 mm) in diameter and spaced less than 33 in. (838 mm) on center.

Manufacturer's Comment: To increase the amount of air flow in cavity walls we recommend a cell vent/ Wire-Bond 3601 or louvered weep (Wire-Bond 3602) every 24".

Anchor Requirements

Corrugated sheet metal anchors - Corrugated sheet metal anchors shall be at least 7/8 in. (22 mm) wide, have a base metal thickness of at least 0.03 in. (22 ga) (0.76 mm), and shall have corrugations with a wavelength of 0.3 to 0.5 in. (7.6 to 12.7 mm) and an amplitude of 0.06 to 0.10 in (1.5 to 2.5 mm).

Corrugated sheet metal anchors shall be placed as follows:

(a) With solid units, embed anchors shall be embedded in the mortar joint and extend into the veneer wythe a minimum of 1-1/2 in. (38 mm), with at least 5/8 in. (16 mm) mortar cover to the outside face.

(b) With hollow units, embed anchors in mortar or grout and extend into the veneer wythe a minimum of 1-1/2 in. (38 mm), with at least 5/8 in. (16 mm) mortar or grout cover to the outside face.

Sheet metal anchors - Sheet metal anchors shall be at least 7/8 in. (22 mm) wide, have a base metal thickness of at least 0.06 in. (16ga) in (1.5 mm) and shall:

(a) have corrugations or

(b) be bent, notched, or punched to provide equivalent performance in pull-out or push-through.

Sheet metal anchors shall be placed as follows:

(a) With solid units, embed anchors in the mortar joint and extend into the veneer wythe a minimum of 1-1/2 in. (38 mm), with at least 5/8 in. (16 mm) mortar cover to the outside face.

(b) With hollow units, embed anchors in mortar or grout and extend into the veneer wythe a minimum of 1-1/2 in. (38 mm), with at least 5/8 in. (16 mm) mortar or grout cover to the outside face.

Page 2

 

 

WIREBOND | 400 ROUNDTREE RD | CHARLOTTE, NC 28224 | 704 525 5554 | 800 849 6722